{"title":"Condition evaluation of power transformers using dissolved gas analysis and dielectric breakdown voltage test","authors":"S. Kumpalavalee, T. Suwanasri, C. Suwanasri, S. Wattanawongpitak, Taratorn Sooksodkiao, Pornthep Tanprasert, Bhakbhum Kaewkamthong","doi":"10.1109/IEECON.2017.8075803","DOIUrl":null,"url":null,"abstract":"This paper proposes the techniques for evaluating power transformer condition based on frequently updated test results. According to planned maintenance, insulation oil is regularly sampled and analyzed in laboratory to determine problems inside main tank by dissolved gas analysis as well as dielectric breakdown voltage test to determine dielectric property of the oil. The dissolved gas analysis is firstly compared with limit values of gases in IEC standard. If values of gases exceed normal condition, the dissolved gases are analyzed by using Duval triangle while dielectric breakdown voltage criterion is reference with the IEC standard. These two methods are subsequently implemented in Microsoft Excel and Visual Basic for Application to evaluate the condition of power transformer and dielectric strength of insulating oil.","PeriodicalId":196081,"journal":{"name":"2017 International Electrical Engineering Congress (iEECON)","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-03-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 International Electrical Engineering Congress (iEECON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEECON.2017.8075803","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

This paper proposes the techniques for evaluating power transformer condition based on frequently updated test results. According to planned maintenance, insulation oil is regularly sampled and analyzed in laboratory to determine problems inside main tank by dissolved gas analysis as well as dielectric breakdown voltage test to determine dielectric property of the oil. The dissolved gas analysis is firstly compared with limit values of gases in IEC standard. If values of gases exceed normal condition, the dissolved gases are analyzed by using Duval triangle while dielectric breakdown voltage criterion is reference with the IEC standard. These two methods are subsequently implemented in Microsoft Excel and Visual Basic for Application to evaluate the condition of power transformer and dielectric strength of insulating oil.
用溶解气体分析和介质击穿电压试验评价电力变压器状态
本文提出了基于频繁更新试验结果的电力变压器状态评估技术。根据计划维修,定期在实验室取样分析绝缘油,通过溶解气体分析和介质击穿电压测试确定主油箱内的问题,确定绝缘油的介电性能。首先将溶解气体分析与IEC标准中气体的限值进行了比较。当气体值超过正常状态时,采用杜瓦尔三角法对溶解气体进行分析,介质击穿电压判据参照IEC标准。随后在Microsoft Excel和Visual Basic for Application中实现了这两种方法,对电力变压器的状况和绝缘油的介电强度进行了评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信