PCC voltage analysis of a hybrid generating system in case of utility side fault

Jae-Hun Jung, Haksoo Kim, E. Nho, T. Chun, Heung-Geun Kim
{"title":"PCC voltage analysis of a hybrid generating system in case of utility side fault","authors":"Jae-Hun Jung, Haksoo Kim, E. Nho, T. Chun, Heung-Geun Kim","doi":"10.1109/VPPC.2012.6422592","DOIUrl":null,"url":null,"abstract":"This paper deals with the PCC voltage analysis of a hybrid generating system consisted with STS, PCS, and load. In case of utility side fault fast and proper control of the PCS output power is necessary to provide undistorted voltage at PCC. The suggested control method guarantees the voltage at PCC can be maintained to the normal value within 1/8 cycles regardless of the fault class. The usefulness of the proposed control method is verified through simulation results.","PeriodicalId":341659,"journal":{"name":"2012 IEEE Vehicle Power and Propulsion Conference","volume":"34 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE Vehicle Power and Propulsion Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/VPPC.2012.6422592","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This paper deals with the PCC voltage analysis of a hybrid generating system consisted with STS, PCS, and load. In case of utility side fault fast and proper control of the PCS output power is necessary to provide undistorted voltage at PCC. The suggested control method guarantees the voltage at PCC can be maintained to the normal value within 1/8 cycles regardless of the fault class. The usefulness of the proposed control method is verified through simulation results.
公用侧故障情况下混合发电系统PCC电压分析
本文研究了由STS、PCS和负载组成的混合发电系统的PCC电压分析。在公用事业侧发生故障时,需要快速、适当地控制PCS输出功率,以提供PCC不失真的电压。所建议的控制方法可以保证PCC电压在1/8个周期内保持到正常值,而不管故障类型。仿真结果验证了所提控制方法的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信