{"title":"Design and analyze detector stress level based oxihaemoglobin (HbO2) in blood","authors":"R. Adil, M. Rochmad","doi":"10.1109/ICICI-BME.2009.5417263","DOIUrl":null,"url":null,"abstract":"Stress, matter which often we hear and experienced of by most old and also young good fellow. The Negative impact generating of for example unstable respiration, having sense frustasi, angry, jumpy and even the productivity degradation. Stress cannot be omitted but be controlled, there assorted is way of to control that is take a rest, arranging respiration, praying. Generally stress by self difficult to feel or detected. For that be made an appliance in order to able to detect condition stress based on signal and rate oxihaemoglobin (HbO2) in blood only by emphasizing the index finger at knowable sensor photo detector so that the condition mount stress somebody presented at LCD in the form of signal. The base on result which have been test-drive by during researcher workmanship got at condition stress own frequency/ beat per bigger minute with rate SaO2 below/under 90% (frequency > 2 Hz).","PeriodicalId":191194,"journal":{"name":"International Conference on Instrumentation, Communication, Information Technology, and Biomedical Engineering 2009","volume":"87 2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Conference on Instrumentation, Communication, Information Technology, and Biomedical Engineering 2009","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICICI-BME.2009.5417263","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Stress, matter which often we hear and experienced of by most old and also young good fellow. The Negative impact generating of for example unstable respiration, having sense frustasi, angry, jumpy and even the productivity degradation. Stress cannot be omitted but be controlled, there assorted is way of to control that is take a rest, arranging respiration, praying. Generally stress by self difficult to feel or detected. For that be made an appliance in order to able to detect condition stress based on signal and rate oxihaemoglobin (HbO2) in blood only by emphasizing the index finger at knowable sensor photo detector so that the condition mount stress somebody presented at LCD in the form of signal. The base on result which have been test-drive by during researcher workmanship got at condition stress own frequency/ beat per bigger minute with rate SaO2 below/under 90% (frequency > 2 Hz).