{"title":"Study on the extension process of AC local arc on wet contaminated insulating surface","authors":"L. Yawei, Z. Qiaogen, Yang Xiaolei, Zhou Jun, Yu Xinzhe","doi":"10.1109/CEIDP.2013.6747106","DOIUrl":null,"url":null,"abstract":"In order to research the extension processes of local arc on wet contaminated insulating surface under AC voltages, high speed camera was used to track the extension process, while, the voltage and leakage current waveforms were recorded by the measurement system. measurement systemObservationally, the extension process can be divided into two categories - The arc foot moving forward along the wet contaminated surface and the arc floating through air. In the case of applied voltage was low, the arc foot extension process was suppressed as the electric field ahead was limited. Arc length went on increasing as it was floating more seriously. When the applied voltage approach or reach flashover voltage, the fast extension of arc foot result in flashover rapidly, and the partial arc didn't had much time to float up. This also indicated that the extension of arc foot was only the result of arc propagation like arc floating instead of surface electric breakdown due to electric field concentration.","PeriodicalId":393969,"journal":{"name":"2013 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","volume":"32 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2013.6747106","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In order to research the extension processes of local arc on wet contaminated insulating surface under AC voltages, high speed camera was used to track the extension process, while, the voltage and leakage current waveforms were recorded by the measurement system. measurement systemObservationally, the extension process can be divided into two categories - The arc foot moving forward along the wet contaminated surface and the arc floating through air. In the case of applied voltage was low, the arc foot extension process was suppressed as the electric field ahead was limited. Arc length went on increasing as it was floating more seriously. When the applied voltage approach or reach flashover voltage, the fast extension of arc foot result in flashover rapidly, and the partial arc didn't had much time to float up. This also indicated that the extension of arc foot was only the result of arc propagation like arc floating instead of surface electric breakdown due to electric field concentration.
湿污染绝缘表面交流局部电弧扩展过程的研究
为了研究交流电压作用下湿污染绝缘表面局部电弧的扩展过程,采用高速摄像机对其扩展过程进行跟踪,测量系统记录了局部电弧的电压和漏电流波形。从观测上看,延伸过程可分为两类:沿湿污染表面向前移动的弧脚和在空气中漂浮的弧脚。在外加电压较低的情况下,由于前方电场有限,弧脚延伸过程受到抑制。圆弧的长度随着浮度的增加而增加。当外加电压接近或达到闪络电压时,弧脚的快速延伸导致闪络迅速发生,部分电弧没有足够的时间浮上。这也说明弧脚的延伸只是电弧漂浮等电弧传播的结果,而不是电场集中引起的表面电击穿。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信