Transformer Core Unbalancing Issue in a Full-Bridge DC-DC Converter with Current Doubler Rectifier

B. Gusev, V. Meleshin, D. Ovchinnikov
{"title":"Transformer Core Unbalancing Issue in a Full-Bridge DC-DC Converter with Current Doubler Rectifier","authors":"B. Gusev, V. Meleshin, D. Ovchinnikov","doi":"10.1109/PEDES.2006.344409","DOIUrl":null,"url":null,"abstract":"Transformer core saturation in a full-bridge, phase-shift DC-DC converter with current doubler rectifier has been considered. Equations allowing to calculate maximum value of the flux density in the core have been obtained. The theoretical analysis and calculations were verified by simulation and experiments of DC-DC converter with 2500 W output power. Main causes of asymmetrical regimes have been revealed and suggested methods preventing a phenomena.","PeriodicalId":262597,"journal":{"name":"2006 International Conference on Power Electronic, Drives and Energy Systems","volume":"5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 International Conference on Power Electronic, Drives and Energy Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEDES.2006.344409","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

Abstract

Transformer core saturation in a full-bridge, phase-shift DC-DC converter with current doubler rectifier has been considered. Equations allowing to calculate maximum value of the flux density in the core have been obtained. The theoretical analysis and calculations were verified by simulation and experiments of DC-DC converter with 2500 W output power. Main causes of asymmetrical regimes have been revealed and suggested methods preventing a phenomena.
带倍流整流器的全桥DC-DC变换器变压器铁心不平衡问题
考虑了带倍流整流器的全桥移相DC-DC变换器的铁心饱和问题。得到了计算堆芯磁通密度最大值的方程。通过输出功率为2500w的DC-DC变换器的仿真和实验验证了理论分析和计算结果。揭示了不对称制度的主要原因,并提出了防止这种现象的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信