New in-situ calibration of diode detectors used in six-port network analyzers

G. Colef, P. Karmel, M. Ettenberg
{"title":"New in-situ calibration of diode detectors used in six-port network analyzers","authors":"G. Colef, P. Karmel, M. Ettenberg","doi":"10.1109/IMTC.1989.36917","DOIUrl":null,"url":null,"abstract":"The authors present a novel method of calibrating the diode detectors used in six-port network analyzers, without disconnecting the diodes. The method uses only a precision variable attenuator or a power meter with no additional directional coupler. The important feature of this method is that no actual measurement of power is required to calibrate the diode detectors for six-port operation. It is very well suited to in-situ calibration of the diode detection circuits for operation of the six-port with pulse signals when the average power detected by the power meter drops to very low levels for low duty cycles. In these cases, the precision variable attenuator method is required. Measurement results are presented.<<ETX>>","PeriodicalId":298343,"journal":{"name":"6th IEEE Conference Record., Instrumentation and Measurement Technology Conference","volume":"38 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1989-04-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"23","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"6th IEEE Conference Record., Instrumentation and Measurement Technology Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMTC.1989.36917","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 23

Abstract

The authors present a novel method of calibrating the diode detectors used in six-port network analyzers, without disconnecting the diodes. The method uses only a precision variable attenuator or a power meter with no additional directional coupler. The important feature of this method is that no actual measurement of power is required to calibrate the diode detectors for six-port operation. It is very well suited to in-situ calibration of the diode detection circuits for operation of the six-port with pulse signals when the average power detected by the power meter drops to very low levels for low duty cycles. In these cases, the precision variable attenuator method is required. Measurement results are presented.<>
六端口网络分析仪中二极管检测器的原位标定
作者提出了一种新的方法,在不断开二极管的情况下校准六端口网络分析仪中使用的二极管检测器。该方法仅使用精密可变衰减器或功率计,没有额外的定向耦合器。该方法的重要特点是不需要实际测量功率来校准二极管检测器的六端口操作。它非常适合于当功率计检测到的平均功率下降到非常低的占空比时,对二极管检测电路进行现场校准,以用于具有脉冲信号的六端口工作。在这种情况下,需要采用精密可变衰减器方法。给出了测量结果
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信