ANALISA BESAR EFISIENSI PEMBANGKIT LISTRIK TENAGA BAYU

Muhammad Adithya Nugraha
{"title":"ANALISA BESAR EFISIENSI PEMBANGKIT LISTRIK TENAGA BAYU","authors":"Muhammad Adithya Nugraha","doi":"10.55445/jt.v10i01.71","DOIUrl":null,"url":null,"abstract":"One of the ideal equipment systems is to have high efficiency. The selection of tools that have high efficiency is certainly necessary for the design of a good system by taking into account the factors of reliability, quality, and cost. In this study, a monitoring system with an application and a data logger system was used to monitor the results of sensor readings at the wind power plant (PLTB) and then store the readings in a data logger. By using the black box methodology to test the monitoring system, the result is that the monitoring system works as expected, namely displaying the readings from the sensors at the generator. Using the monitoring system, the measurement process is carried out to find the efficiency value of the PLTB. the comparison of electricity use in public street light facilities when connected to PLTB and when only using batteries and inverters can improve the total remaining voltage on the battery by 89.74%. For the value of the efficiency of the power generated by the generator with the energy used at a 30W lamp load of 2.61%. The data is the result of calculations from the sensor readings that are stored in the data logger.","PeriodicalId":442343,"journal":{"name":"Jurnal Teknovasi","volume":"63 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-04-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Teknovasi","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.55445/jt.v10i01.71","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

One of the ideal equipment systems is to have high efficiency. The selection of tools that have high efficiency is certainly necessary for the design of a good system by taking into account the factors of reliability, quality, and cost. In this study, a monitoring system with an application and a data logger system was used to monitor the results of sensor readings at the wind power plant (PLTB) and then store the readings in a data logger. By using the black box methodology to test the monitoring system, the result is that the monitoring system works as expected, namely displaying the readings from the sensors at the generator. Using the monitoring system, the measurement process is carried out to find the efficiency value of the PLTB. the comparison of electricity use in public street light facilities when connected to PLTB and when only using batteries and inverters can improve the total remaining voltage on the battery by 89.74%. For the value of the efficiency of the power generated by the generator with the energy used at a 30W lamp load of 2.61%. The data is the result of calculations from the sensor readings that are stored in the data logger.
对BAYU发电厂效率的分析
高效是理想的设备系统之一。考虑到可靠性、质量和成本等因素,选择效率高的工具是设计一个好的系统的必要条件。在本研究中,使用了一个带有应用程序和数据记录器系统的监测系统来监测风力发电厂(PLTB)传感器读数的结果,然后将读数存储在数据记录器中。通过使用黑箱方法测试监测系统,结果是监测系统按预期工作,即显示来自发电机传感器的读数。利用该监测系统,进行了测量过程,找出了PLTB的效率值。将公共路灯设施的用电量与仅使用电池和逆变器时的用电量进行比较,可以将电池上的总剩余电压提高89.74%。表示发电机在30W灯负载下使用的能量为2.61%时所产生的功率的效率值。数据是存储在数据记录仪中的传感器读数的计算结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信