{"title":"Comparative Evaluation of CT Angiography Images Applied with CE-BOOST","authors":"Gi-Jin Kwon, Soo-Yeong Lee, Seul-Bi Lee, Sang-Hyeon Jeon, Seong-Su Shin, Sang-Heon Jang, P. Jeon","doi":"10.31320/jksct.2022.24.2.43","DOIUrl":null,"url":null,"abstract":"With the rapid development of image processing technology using Deep Learning Reconstruction (DLR), Contrast Enhancement Boost Technique (CE-Boost) was developed using a subtraction technique for contrast-enhanced images. In this study, CE-Boost was applied to CT angiography (CTA) to conduct quantitative evaluation. Lower extremity, neck and abdominal angiography images from 60 people quantitatively analyzed the difference between conventional enhanced image and CE-Boost image quality by measuring signal to noise ratio (SNR), noise and contrast to noise ratio (CNR) values. When CE-Boost technology was applied to CTA, Noise was reduced and SNR and CNR values were increased by more than 50% compared to conventional images. CE-Boost reduces noise, increases SNR and CNR values in CTA, and helps improve overall image quality.","PeriodicalId":272693,"journal":{"name":"Korean Society of Computed Tomographic Technology","volume":"4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Korean Society of Computed Tomographic Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31320/jksct.2022.24.2.43","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
With the rapid development of image processing technology using Deep Learning Reconstruction (DLR), Contrast Enhancement Boost Technique (CE-Boost) was developed using a subtraction technique for contrast-enhanced images. In this study, CE-Boost was applied to CT angiography (CTA) to conduct quantitative evaluation. Lower extremity, neck and abdominal angiography images from 60 people quantitatively analyzed the difference between conventional enhanced image and CE-Boost image quality by measuring signal to noise ratio (SNR), noise and contrast to noise ratio (CNR) values. When CE-Boost technology was applied to CTA, Noise was reduced and SNR and CNR values were increased by more than 50% compared to conventional images. CE-Boost reduces noise, increases SNR and CNR values in CTA, and helps improve overall image quality.