MVDC Application: Switching Processes AC-to-DC, DC -to- AC and Imbalance Mitigation through DC Mode

T. C. D. Oliveira, F. V. Overbeeke, V. Ćuk, E. Jong
{"title":"MVDC Application: Switching Processes AC-to-DC, DC -to- AC and Imbalance Mitigation through DC Mode","authors":"T. C. D. Oliveira, F. V. Overbeeke, V. Ćuk, E. Jong","doi":"10.1109/ISGTEurope.2019.8905558","DOIUrl":null,"url":null,"abstract":"Proposal Flexible AC/DC-link (FDCL) testing is devoted to its ancillary services and to its interaction with the network. In the laboratory identify, tests are being performed with regards to the flexibility of the operation, and the level of efficiency and improvement on power quality that can be gained with the control of the system. The present study begins by examining the switching procedure AC-to-DC and DC-to-AC of the FDCL and then, as an initial testing phase, the aspects regarding its improvement through ancillary services (Imbalance mitigation) in the DC mode are tested and verified for real scenarios.","PeriodicalId":305933,"journal":{"name":"2019 IEEE PES Innovative Smart Grid Technologies Europe (ISGT-Europe)","volume":"298 2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE PES Innovative Smart Grid Technologies Europe (ISGT-Europe)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISGTEurope.2019.8905558","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Proposal Flexible AC/DC-link (FDCL) testing is devoted to its ancillary services and to its interaction with the network. In the laboratory identify, tests are being performed with regards to the flexibility of the operation, and the level of efficiency and improvement on power quality that can be gained with the control of the system. The present study begins by examining the switching procedure AC-to-DC and DC-to-AC of the FDCL and then, as an initial testing phase, the aspects regarding its improvement through ancillary services (Imbalance mitigation) in the DC mode are tested and verified for real scenarios.
MVDC应用:交换流程AC- DC、DC - AC和通过DC方式缓解不平衡
柔性AC/DC-link (FDCL)测试致力于其辅助服务及其与网络的交互。在实验室鉴定中,正在进行有关操作灵活性、效率水平和通过控制系统可以获得的电能质量改进的测试。本研究首先考察了FDCL的交流到直流和直流到交流的转换过程,然后,作为初始测试阶段,在直流模式下通过辅助服务(失衡缓解)对其进行改进的方面进行了测试和验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信