Behavior and Design of High-Strength RC Walls

J. Wallace
{"title":"Behavior and Design of High-Strength RC Walls","authors":"J. Wallace","doi":"10.14359/5903","DOIUrl":null,"url":null,"abstract":"Use of high-strength reinforced concrete walls in regions of high seismic risk is evaluated using current U.S. code provisions, an example building parametric studies, and experimental results. The format of current U.S. code provisions for structural walls promotes the use of high-strength concrete; however, the use of these provisions has not been evaluated for high-strength concrete. Analytical studies of building systems utilizing slender walls indicate that there is not a significant advantage associated with the use of high-strength concrete walls and that this advantage tends to diminish with increasing concrete strength. Evaluation of test results conducted in Japan for low-aspect ratio walls indicates that ACI 318-95 requirements do no represent the observed shear strength well.","PeriodicalId":208613,"journal":{"name":"SP-176: High-Strength Concrete in Seismic Regions","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1998-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"SP-176: High-Strength Concrete in Seismic Regions","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14359/5903","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

Abstract

Use of high-strength reinforced concrete walls in regions of high seismic risk is evaluated using current U.S. code provisions, an example building parametric studies, and experimental results. The format of current U.S. code provisions for structural walls promotes the use of high-strength concrete; however, the use of these provisions has not been evaluated for high-strength concrete. Analytical studies of building systems utilizing slender walls indicate that there is not a significant advantage associated with the use of high-strength concrete walls and that this advantage tends to diminish with increasing concrete strength. Evaluation of test results conducted in Japan for low-aspect ratio walls indicates that ACI 318-95 requirements do no represent the observed shear strength well.
高强钢筋混凝土墙体的性能与设计
在高地震风险地区使用高强度钢筋混凝土墙的评估使用现行美国规范规定,一个例子建筑参数研究和实验结果。现行美国规范规定的结构墙格式提倡使用高强度混凝土;然而,这些规定的使用尚未对高强度混凝土进行评估。对利用细长墙体的建筑系统的分析研究表明,使用高强度混凝土墙体并没有显著的优势,而且这种优势随着混凝土强度的增加而减弱。在日本进行的低纵横比墙体试验结果评估表明,ACI 318-95要求不能很好地代表观察到的抗剪强度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信