Analysis of VFTO in 1000kV GIS

Xin Pan
{"title":"Analysis of VFTO in 1000kV GIS","authors":"Xin Pan","doi":"10.1109/GEMCCON50979.2020.9456677","DOIUrl":null,"url":null,"abstract":"With the development of UHV (Ultra High Voltage) transmission technology, GIS(Gas Insulated Substation) is usually used at all levels of substations, but it will produce VFTO (Very Fast Transient Overvoltage)when operating its isolating switch. It has the characteristics of large amplitude, high frequency and fast fluctuation. It is easy to cause safety problems such as electrical insulation breakdown of GIS and related equipment. In this paper, the VFTO generated in the GIS of the 1000kV UHV transmission system is taken as the research object. Aiming at this problem, the two suppression measures including metal oxide surge arrester and parallel brake resistance are analyzed and compared by using ATP-EMTP. The simulation result show that both of these measures can effectively suppress the impact of VFTO on the entire power system.","PeriodicalId":194675,"journal":{"name":"2020 6th Global Electromagnetic Compatibility Conference (GEMCCON)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 6th Global Electromagnetic Compatibility Conference (GEMCCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/GEMCCON50979.2020.9456677","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

With the development of UHV (Ultra High Voltage) transmission technology, GIS(Gas Insulated Substation) is usually used at all levels of substations, but it will produce VFTO (Very Fast Transient Overvoltage)when operating its isolating switch. It has the characteristics of large amplitude, high frequency and fast fluctuation. It is easy to cause safety problems such as electrical insulation breakdown of GIS and related equipment. In this paper, the VFTO generated in the GIS of the 1000kV UHV transmission system is taken as the research object. Aiming at this problem, the two suppression measures including metal oxide surge arrester and parallel brake resistance are analyzed and compared by using ATP-EMTP. The simulation result show that both of these measures can effectively suppress the impact of VFTO on the entire power system.
1000kV GIS中VFTO的分析
随着特高压(UHV)输电技术的发展,气体绝缘变电站(GIS)通常用于各级变电站,但在操作其隔离开关时会产生VFTO (Very Fast Transient Overvoltage)。它具有振幅大、频率高、波动快的特点。易造成GIS及相关设备电气绝缘击穿等安全问题。本文以1000kV特高压输电系统的GIS中产生的VFTO为研究对象。针对这一问题,利用ATP-EMTP对金属氧化物避雷器和并联制动电阻两种抑制措施进行了分析比较。仿真结果表明,这两种措施都能有效地抑制VFTO对整个电力系统的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信