C. Paulus, H. Wieder, C. Musewald, H. Lossau, R. Thewes
{"title":"A fully integrated CMOS sensor system for chronocoulometry","authors":"C. Paulus, H. Wieder, C. Musewald, H. Lossau, R. Thewes","doi":"10.1109/ICSENS.2003.1279163","DOIUrl":null,"url":null,"abstract":"In this paper, a monolithically integrated electrochemical sensor system based on a CMOS chip is presented, which allows to per-form microminiaturized chronocoulometric analyses on chip with high sensitivity and large bandwidth. The chip is based on a standard 0.5 /spl mu/m CMOS technology extended by gold electrodes on the chip's surface. A possible exploration of this approach is the realization of electrochemical sensors, e.g. electronic DNA arrays, for the analysis of liquids.","PeriodicalId":369277,"journal":{"name":"Proceedings of IEEE Sensors 2003 (IEEE Cat. No.03CH37498)","volume":"51 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-10-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of IEEE Sensors 2003 (IEEE Cat. No.03CH37498)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENS.2003.1279163","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
In this paper, a monolithically integrated electrochemical sensor system based on a CMOS chip is presented, which allows to per-form microminiaturized chronocoulometric analyses on chip with high sensitivity and large bandwidth. The chip is based on a standard 0.5 /spl mu/m CMOS technology extended by gold electrodes on the chip's surface. A possible exploration of this approach is the realization of electrochemical sensors, e.g. electronic DNA arrays, for the analysis of liquids.