Spectroscopy on thick HgI/sub 2/ detectors: a comparison between planar and pixelated electrodes

J. Baciak, Zhong He
{"title":"Spectroscopy on thick HgI/sub 2/ detectors: a comparison between planar and pixelated electrodes","authors":"J. Baciak, Zhong He","doi":"10.1109/NSSMIC.2002.1239349","DOIUrl":null,"url":null,"abstract":"Thick mercuric iodide (HgI/sub 2/) detectors are investigated as potential room temperature gamma-ray spectrometers. By using pixelated anodes the induced charge on the electrode is dependent mainly on electron movement and is almost independent of the depth of interaction. Moreover, by reading out the planar cathode signal simultaneously, the depth of interaction can be determined and any effects of electron charge loss can he corrected. By combining these two methods (pixelated anodes and depth sensing), the resolution from 1 cm thick HgI/sub 2/ devices can be improved to 1.4% FWHM when using a Cs-137 point source. These results were made using a modest electric field (2500 V/cm) and relatively short shaping times (4-16 /spl mu/s) for HgI/sub 2./ A comparison between conventional planar readout and single polarity charge sensing techniques with wide band-gap semiconductors is discussed.","PeriodicalId":385259,"journal":{"name":"2002 IEEE Nuclear Science Symposium Conference Record","volume":"33 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"26","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2002 IEEE Nuclear Science Symposium Conference Record","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2002.1239349","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 26

Abstract

Thick mercuric iodide (HgI/sub 2/) detectors are investigated as potential room temperature gamma-ray spectrometers. By using pixelated anodes the induced charge on the electrode is dependent mainly on electron movement and is almost independent of the depth of interaction. Moreover, by reading out the planar cathode signal simultaneously, the depth of interaction can be determined and any effects of electron charge loss can he corrected. By combining these two methods (pixelated anodes and depth sensing), the resolution from 1 cm thick HgI/sub 2/ devices can be improved to 1.4% FWHM when using a Cs-137 point source. These results were made using a modest electric field (2500 V/cm) and relatively short shaping times (4-16 /spl mu/s) for HgI/sub 2./ A comparison between conventional planar readout and single polarity charge sensing techniques with wide band-gap semiconductors is discussed.
厚HgI/ sub2 /探测器的光谱学:平面电极和像素电极的比较
研究了厚碘化汞(HgI/sub 2/)探测器作为潜在的室温伽马射线能谱仪。采用像素化阳极,电极上的感应电荷主要取决于电子的运动,几乎与相互作用的深度无关。此外,通过同时读出平面阴极信号,可以确定相互作用的深度,并可以纠正电子电荷损失的任何影响。结合像素化阳极和深度传感两种方法,当使用Cs-137点源时,1 cm厚HgI/sub 2/器件的分辨率可以提高到1.4% FWHM。对于HgI/sub 2,这些结果是在适度的电场(2500 V/cm)和相对较短的成型时间(4-16 /spl mu/s)下获得的。讨论了传统平面读出技术与宽带隙半导体单极性电荷传感技术的比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信