DVR with auxiliary DC voltage source provided by a high power diode based rectifier used in MV connection substations

G. Nicolaescu, H. Andrei, Stefan Raduulescu
{"title":"DVR with auxiliary DC voltage source provided by a high power diode based rectifier used in MV connection substations","authors":"G. Nicolaescu, H. Andrei, Stefan Raduulescu","doi":"10.1109/ATEE.2015.7133888","DOIUrl":null,"url":null,"abstract":"This paper presents the Dynamic Voltage Restorer (DVR) response study in cases of voltage sags occurrence in the electrical distribution networks with connection substation topology. Usually, these voltage disturbances are caused by faults that can occur on the lines connected to the same bus bar as the main feeder or even on main feeder of connection substation. A DVR that uses a diode based rectifier as a DC voltage source, supplied by the back-up feeder of connection substation, has been modeled in Matlab/Simulink. Severe faults on the lines adjacent to main feeder and back-up feeder and also faults on main feeder, with real impact for the magnitude of voltage supplied to end-users connected to the electrical network downstream of the connection substation bus bars, have been simulated. The DVR response has been studied for these fault conditions. The obtained results prove the effectiveness of the chosen topology of this series Custom Power device for voltage magnitude disturbances mitigation in distribution networks.","PeriodicalId":103513,"journal":{"name":"2015 9th International Symposium on Advanced Topics in Electrical Engineering (ATEE)","volume":"76 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-05-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 9th International Symposium on Advanced Topics in Electrical Engineering (ATEE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ATEE.2015.7133888","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This paper presents the Dynamic Voltage Restorer (DVR) response study in cases of voltage sags occurrence in the electrical distribution networks with connection substation topology. Usually, these voltage disturbances are caused by faults that can occur on the lines connected to the same bus bar as the main feeder or even on main feeder of connection substation. A DVR that uses a diode based rectifier as a DC voltage source, supplied by the back-up feeder of connection substation, has been modeled in Matlab/Simulink. Severe faults on the lines adjacent to main feeder and back-up feeder and also faults on main feeder, with real impact for the magnitude of voltage supplied to end-users connected to the electrical network downstream of the connection substation bus bars, have been simulated. The DVR response has been studied for these fault conditions. The obtained results prove the effectiveness of the chosen topology of this series Custom Power device for voltage magnitude disturbances mitigation in distribution networks.
DVR辅助直流电压源由大功率二极管整流器提供,用于中压连接变电站
本文研究了具有连接变电站拓扑结构的配电网电压跌落时动态电压恢复器(DVR)的响应问题。通常,这些电压扰动是由故障引起的,这些故障可能发生在与主馈线连接的同一母线上,甚至可能发生在连接变电站的主馈线上。在Matlab/Simulink中对一种采用二极管整流器作为直流电压源,由连接变电站后备馈线供电的DVR进行了建模。模拟了主馈线和备用馈线相邻线路的严重故障以及主馈线的严重故障,这些故障对连接变电站母线下游接入电网的最终用户供电电压的大小有实际影响。对这些故障条件下的DVR响应进行了研究。所得结果证明了该系列自定义电源器件所选择的拓扑结构对减轻配电网电压幅值干扰的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信