Development of a thin-film thermocouple matrix for in-situ temperature measurement in a lithium ion pouch cell

N. Martiny, Jan Geder, Yuxi Wang, Werner Kraus, A. Jossen
{"title":"Development of a thin-film thermocouple matrix for in-situ temperature measurement in a lithium ion pouch cell","authors":"N. Martiny, Jan Geder, Yuxi Wang, Werner Kraus, A. Jossen","doi":"10.1109/ICSENS.2013.6688485","DOIUrl":null,"url":null,"abstract":"As cooling systems in battery systems lead to a falsified temperature measurement when surface based temperature monitoring techniques are applied, the development of a sensor for in-situ temperature monitoring is crucial. The authors present therefore different restrictions that need to be considered when designing such a sensor. First prototypes are developed as a proof of concept of using a common potential for a thermocouple matrix that will later provide a space resolved temperature monitoring in a cell. The influence of the sensor on the cell and vice versa is investigated and improvements for further design steps are elaborated.","PeriodicalId":258260,"journal":{"name":"2013 IEEE SENSORS","volume":"12 5","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-12-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE SENSORS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENS.2013.6688485","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13

Abstract

As cooling systems in battery systems lead to a falsified temperature measurement when surface based temperature monitoring techniques are applied, the development of a sensor for in-situ temperature monitoring is crucial. The authors present therefore different restrictions that need to be considered when designing such a sensor. First prototypes are developed as a proof of concept of using a common potential for a thermocouple matrix that will later provide a space resolved temperature monitoring in a cell. The influence of the sensor on the cell and vice versa is investigated and improvements for further design steps are elaborated.
用于锂离子袋状电池原位温度测量的薄膜热电偶矩阵的研制
当应用表面温度监测技术时,电池系统中的冷却系统会导致温度测量的不准确,因此开发用于现场温度监测的传感器至关重要。因此,作者提出了在设计这种传感器时需要考虑的不同限制。第一个原型是作为使用热电偶矩阵的共同电位的概念证明而开发的,该矩阵随后将在单元中提供空间分辨温度监测。研究了传感器对电池的影响,并阐述了进一步设计步骤的改进。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信