Effect of the Coupling Method between a Sample and a Transducer on the Photoacoustic Image in Photoacoustic Microscopy

Hiromichi Shimizu, M. Kasai, T. Sawada, Y. Gohshi
{"title":"Effect of the Coupling Method between a Sample and a Transducer on the Photoacoustic Image in Photoacoustic Microscopy","authors":"Hiromichi Shimizu, M. Kasai, T. Sawada, Y. Gohshi","doi":"10.5111/BUNKOU.33.249","DOIUrl":null,"url":null,"abstract":"The effect on PA image of the method of coupling the sample and detector was investigated experimentally. Three coupling methods, i. e. rigid coupling, coupling using liquids, and coupling using sheet materials, were tested in terms of signal intensity and image distortion. Highly viscous liquid proved to be nearly as good as the rigid combination in terms of signal intensity and distortion over the frequency range 200 Hz to 200 kHz. Taking separability into consideration, the use of viscous liquid under pressure is the most practical coupling method.","PeriodicalId":199016,"journal":{"name":"Journal of the Spectroscopical Society of Japan","volume":"5 9","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1984-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Spectroscopical Society of Japan","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5111/BUNKOU.33.249","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The effect on PA image of the method of coupling the sample and detector was investigated experimentally. Three coupling methods, i. e. rigid coupling, coupling using liquids, and coupling using sheet materials, were tested in terms of signal intensity and image distortion. Highly viscous liquid proved to be nearly as good as the rigid combination in terms of signal intensity and distortion over the frequency range 200 Hz to 200 kHz. Taking separability into consideration, the use of viscous liquid under pressure is the most practical coupling method.
样品与换能器耦合方法对光声显微镜中光声图像的影响
实验研究了样品与探测器耦合的方法对PA成像的影响。从信号强度和图像畸变两方面对刚性耦合、液体耦合和片状材料耦合三种耦合方式进行了测试。在200赫兹到200千赫的频率范围内,高粘性液体在信号强度和失真方面几乎与刚性组合一样好。考虑可分离性,使用有压力的粘性液体是最实用的耦合方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信