Evaluation of zygomatic bone region for placement of quad zygomatic implants using CBCT in postmenopausal women

Neelam Manoj Vaibhav, R. Amirisetty, Rajesh Nichenametla, Gonabhavi Siri Chandana, Santhi Prathyusha M, Naresh Kumar C, B. T. Reddy
{"title":"Evaluation of zygomatic bone region for placement of quad zygomatic implants using CBCT in postmenopausal women","authors":"Neelam Manoj Vaibhav, R. Amirisetty, Rajesh Nichenametla, Gonabhavi Siri Chandana, Santhi Prathyusha M, Naresh Kumar C, B. T. Reddy","doi":"10.18231/J.IJMI.2021.010","DOIUrl":null,"url":null,"abstract":"Insufficient height and width of the alveolar ridge at the implant site remains with inadequate bone volume following extraction in older age people especially in postmenopausal women. Postmenopausal women are susceptible to primary osteoporosis where more bone resorption than formation is seen resulting in decreased bone mass. Hence the present study aims to evaluate the zygomatic bone region for placement of quad zygomatic implants using CBCT.: A total of 120 CBCT images of female patients who were between the age group of 45 yrs to 65 yrs were taken. The zygomatic bone was evaluated for pneumatisation zones and thickness of zygomatic bone at three different regions i.e., superior, middle and inferior at nine points on zygoma bone along with bone to implant contact (BIC) region using virtual software. The largest thickness in the superior, middle and inferior regions were at Point A2(8.01+/-2.10 mm), Point B2 (7.01+/-1.62 mm), and Point C1 (6.65+/-1.64 mm), respectively. The virtually placed implants at Point A3 (15.92+/-4.16 mm) and Point B2 (12.02+/-3.62 mm) had the highest BICs. : To obtain the largest BICs, results suggested that the posterosuperior region (Point A3) and the centre of zygoma (Point B1) were the optimal places for the placement of quad zygomatic implants.","PeriodicalId":282949,"journal":{"name":"IP International Journal of Maxillofacial Imaging","volume":"45 3","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IP International Journal of Maxillofacial Imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18231/J.IJMI.2021.010","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Insufficient height and width of the alveolar ridge at the implant site remains with inadequate bone volume following extraction in older age people especially in postmenopausal women. Postmenopausal women are susceptible to primary osteoporosis where more bone resorption than formation is seen resulting in decreased bone mass. Hence the present study aims to evaluate the zygomatic bone region for placement of quad zygomatic implants using CBCT.: A total of 120 CBCT images of female patients who were between the age group of 45 yrs to 65 yrs were taken. The zygomatic bone was evaluated for pneumatisation zones and thickness of zygomatic bone at three different regions i.e., superior, middle and inferior at nine points on zygoma bone along with bone to implant contact (BIC) region using virtual software. The largest thickness in the superior, middle and inferior regions were at Point A2(8.01+/-2.10 mm), Point B2 (7.01+/-1.62 mm), and Point C1 (6.65+/-1.64 mm), respectively. The virtually placed implants at Point A3 (15.92+/-4.16 mm) and Point B2 (12.02+/-3.62 mm) had the highest BICs. : To obtain the largest BICs, results suggested that the posterosuperior region (Point A3) and the centre of zygoma (Point B1) were the optimal places for the placement of quad zygomatic implants.
使用CBCT评估绝经后妇女颧骨区域放置四颧植入物的效果
老年人特别是绝经后妇女拔牙后牙槽嵴高度和宽度不足,骨体积不足。绝经后妇女易患原发性骨质疏松症,骨质吸收多于形成导致骨量减少。因此,本研究旨在利用CBCT评估颧骨区域放置四头颧骨植入物。:选取年龄在45 ~ 65岁的女性患者共120张CBCT图像。利用虚拟软件对颧骨上、中、下九个点三个不同区域以及骨与种植体接触区(BIC)进行充气区和颧骨厚度的评估。A2(8.01+/-2.10 mm)、B2 (7.01+/-1.62 mm)、C1 (6.65+/-1.64 mm)为上、中、下三区最大厚度。在A3点(15.92+/-4.16 mm)和B2点(12.02+/-3.62 mm)虚拟放置种植体的BICs最高。为了获得最大的BICs,结果表明后上区(A3点)和颧骨中心(B1点)是放置四颧假体的最佳位置。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信