eBP: Frequent and Comfortable Blood Pressure Monitoring from Inside Human's Ears

Nam Bui, Nhat Pham, Anh-Hoang Truong, Phuc Nguyen, Jianliang Xiao, R. Deterding, Thang N. Dinh
{"title":"eBP: Frequent and Comfortable Blood Pressure Monitoring from Inside Human's Ears","authors":"Nam Bui, Nhat Pham, Anh-Hoang Truong, Phuc Nguyen, Jianliang Xiao, R. Deterding, Thang N. Dinh","doi":"10.1145/3400713.3400721","DOIUrl":null,"url":null,"abstract":"Diagnosing hypertension or hemodialysis requires patients to carry a blood pressure (BP) monitoring device for 24 hours. Th erefore, wearing the wrist/arm-based BP monitoring device, in this case, has a signifi cant impact on users' daily activities. To address the problem, we developed eBP, an ear-worn device that measures blood pressure from inside the ear. Th rough the evaluation of 35 subjects, eBP can achieve the average error of 1.8 mmHg for systolic BP and -3.1 mmHg for diastolic BP with the standard deviation error of 7.2 mmHg and 7.9 mmHg, respectively.","PeriodicalId":213775,"journal":{"name":"GetMobile Mob. Comput. Commun.","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-05-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"GetMobile Mob. Comput. Commun.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/3400713.3400721","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Diagnosing hypertension or hemodialysis requires patients to carry a blood pressure (BP) monitoring device for 24 hours. Th erefore, wearing the wrist/arm-based BP monitoring device, in this case, has a signifi cant impact on users' daily activities. To address the problem, we developed eBP, an ear-worn device that measures blood pressure from inside the ear. Th rough the evaluation of 35 subjects, eBP can achieve the average error of 1.8 mmHg for systolic BP and -3.1 mmHg for diastolic BP with the standard deviation error of 7.2 mmHg and 7.9 mmHg, respectively.
eBP:从人耳内部进行频繁和舒适的血压监测
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信