{"title":"An effective approach for ATC enhancement with FACTS device - A case study","authors":"R. K. Pandey, D. S. Chaitanya","doi":"10.1109/APCET.2012.6301989","DOIUrl":null,"url":null,"abstract":"This paper presents an acceptable solution for Available Transfer Capability (ATC) enhancement. This has been accomplished with Static Synchronous Series Compensation (SSSC) and Unified Power Flow Controller (UPFC). The optimal usage of SSSC and UPFC leads to maximization of Total Transfer Capability (TTC). To illustrate the applicability of proposed approach and gain confidence, a case study has been done on a modified IEEE 30 bus system divided into two areas with eight interconnecting transmission lines using PSAT (Power System Analysis Tool Box) software. Calculations of ATC have been done with PSAT. The results demonstrate the capability of approach in ATC enhancement which may form a basis for existing transmission lines upgradation.","PeriodicalId":184844,"journal":{"name":"2012 International Conference on Advances in Power Conversion and Energy Technologies (APCET)","volume":"102 8","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-09-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 International Conference on Advances in Power Conversion and Energy Technologies (APCET)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APCET.2012.6301989","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

This paper presents an acceptable solution for Available Transfer Capability (ATC) enhancement. This has been accomplished with Static Synchronous Series Compensation (SSSC) and Unified Power Flow Controller (UPFC). The optimal usage of SSSC and UPFC leads to maximization of Total Transfer Capability (TTC). To illustrate the applicability of proposed approach and gain confidence, a case study has been done on a modified IEEE 30 bus system divided into two areas with eight interconnecting transmission lines using PSAT (Power System Analysis Tool Box) software. Calculations of ATC have been done with PSAT. The results demonstrate the capability of approach in ATC enhancement which may form a basis for existing transmission lines upgradation.
一种利用FACTS装置增强ATC的有效方法-一个案例研究
本文提出了一种可接受的提高可用传输能力(ATC)的方案。这是通过静态同步串联补偿(SSSC)和统一潮流控制器(UPFC)来实现的。SSSC和UPFC的最佳使用可以使总传输能力(TTC)最大化。为了说明所提出的方法的适用性并获得信心,使用PSAT(电力系统分析工具箱)软件对一个改进的IEEE 30总线系统进行了案例研究,该系统分为两个区域,有八条互连的传输线。用PSAT进行了ATC的计算。结果证明了该方法在ATC增强中的能力,为现有输电线路的升级提供了基础。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信