Perioperative changes in coagulation and platelet contribution to clot strength after transcatheter aortic valve implantation: A study using thromboelastography and conventional markers.
{"title":"Perioperative changes in coagulation and platelet contribution to clot strength after transcatheter aortic valve implantation: A study using thromboelastography and conventional markers.","authors":"Takeyuki Sajima, Mae Harada, Taichi Onimaru, Takahiro Honjo, Taisuke Mizuguchi, Atsushi Yasuda, Shigehito Swamura, Hirofumi Hioki, Yusuke Watanabe","doi":"10.1177/02676591231216658","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Thrombotic and haemorrhagic complications have been reported following transcatheter aortic valve implantation (TAVI). However, few reports have studied perioperative changes in coagulation and platelet function after TAVI. Furthermore, there are no clear guidelines for antithrombotic therapy. This study aimed to examine the perioperative changes in coagulation and platelet contribution to clot strength after TAVI using thromboelastography (TEG 6s; Hemonetics).</p><p><strong>Methods: </strong>This prospective observational study included 15 patients scheduled to undergo TAVI for severe aortic stenosis. TEG 6s global haemostasis was used to record three measurements: on the day of surgery (immediately before the operation) and postoperative days 1 and 3. The reaction time R to thrombosis; K and α, which represent the rate of thrombosis; and the maximum amplitude (MA) were measured from the kaolin thromboelastography (TEG) curves. The coagulation index (CI) was calculated from the measurement results to assess thrombotic tendency. In addition, MA was converted to elastic clot strength, and platelet function was assessed by the difference, G<sub>p</sub>, in elastic strength depending on platelet activation.</p><p><strong>Results: </strong>R and K decreased, and α tended to increase in kaolin TEG on days 1 and 3 after TAVI, indicating elevated coagulation function compared with the preoperative period, but MA and CI did not show significant changes. G<sub>p</sub> decreased significantly on days 1 and 3, suggesting a decrease in the platelet contribution to clot strength.</p><p><strong>Conclusions: </strong>Compared with the preoperative period, coagulation tended to increase, and platelet contribution to clot strength decreased from days 1 to 3 after TAVI.</p>","PeriodicalId":49707,"journal":{"name":"Perfusion-Uk","volume":" ","pages":"1700-1707"},"PeriodicalIF":1.1000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Perfusion-Uk","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/02676591231216658","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/11/14 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: Thrombotic and haemorrhagic complications have been reported following transcatheter aortic valve implantation (TAVI). However, few reports have studied perioperative changes in coagulation and platelet function after TAVI. Furthermore, there are no clear guidelines for antithrombotic therapy. This study aimed to examine the perioperative changes in coagulation and platelet contribution to clot strength after TAVI using thromboelastography (TEG 6s; Hemonetics).
Methods: This prospective observational study included 15 patients scheduled to undergo TAVI for severe aortic stenosis. TEG 6s global haemostasis was used to record three measurements: on the day of surgery (immediately before the operation) and postoperative days 1 and 3. The reaction time R to thrombosis; K and α, which represent the rate of thrombosis; and the maximum amplitude (MA) were measured from the kaolin thromboelastography (TEG) curves. The coagulation index (CI) was calculated from the measurement results to assess thrombotic tendency. In addition, MA was converted to elastic clot strength, and platelet function was assessed by the difference, Gp, in elastic strength depending on platelet activation.
Results: R and K decreased, and α tended to increase in kaolin TEG on days 1 and 3 after TAVI, indicating elevated coagulation function compared with the preoperative period, but MA and CI did not show significant changes. Gp decreased significantly on days 1 and 3, suggesting a decrease in the platelet contribution to clot strength.
Conclusions: Compared with the preoperative period, coagulation tended to increase, and platelet contribution to clot strength decreased from days 1 to 3 after TAVI.
期刊介绍:
Perfusion is an ISI-ranked, peer-reviewed scholarly journal, which provides current information on all aspects of perfusion, oxygenation and biocompatibility and their use in modern cardiac surgery. The journal is at the forefront of international research and development and presents an appropriately multidisciplinary approach to perfusion science.