Ashley L Sweet, Christopher R Connelly, Elizabeth N Dewey, David L Scott
{"title":"The Effect of Perfusate Temperature on Delayed Graft Function in Deceased Donor Renal Transplantation.","authors":"Ashley L Sweet, Christopher R Connelly, Elizabeth N Dewey, David L Scott","doi":"10.1177/15269248231212920","DOIUrl":null,"url":null,"abstract":"<p><p><b>Introduction:</b> Renal allograft hypothermic machine perfusion results in a decreased incidence of delayed graft function compared with static cold storage. Ensuring perfusate temperatures remain within the target range of 4-10 °C may impact delayed graft function rates. <b>Project Aims:</b> To identify whether this target was achieved and, if not, whether higher perfusate temperature was associated with delayed graft function. <b>Design:</b> In this retrospective cohort study, transplanted grafts from deceased donors placed on hypothermic machine perfusion pump from June 2019 to August 2020 were analyzed. Measurements were recovered after 5, 15, 60, and 180 min of perfusion. Univariable and multivariable analyses were performed to identify predictors of delayed graft function. <b>Results:</b> A total of 113 grafts from 94 donors were analyzed. Of these, 21 (19%) developed delayed graft function. On univariable logistic regression, variables associated with delayed graft function included older donor age (OR 1.08, <i>P</i> = .002), higher Kidney Donor Profile Index score (OR 1.03, <i>P</i> = .024), and higher 5-min perfusate temperature (T5 min; OR 1.49, <i>P</i> = .014). A higher T5 min was also associated with delayed graft function in multivariable logistic regression models (OR 1.58, <i>P</i> = .005; OR 1.37, <i>P</i> = .08). Grafts with T5 min >10 °C were more likely to experience delayed graft function than those with T5 min <10 °C (OR 4.5, <i>P</i> = .006). <b>Conclusion:</b> Higher early perfusate temperature was an independent predictor of delayed graft function and may be due to inadequate cooling of the circuit prior to placing grafts on pump. Quality improvement initiatives targeting early perfusate temperatures of ≤10 °C may reduce delayed graft function incidence.</p>","PeriodicalId":20671,"journal":{"name":"Progress in Transplantation","volume":" ","pages":"341-347"},"PeriodicalIF":0.6000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Progress in Transplantation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15269248231212920","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/11/14 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: Renal allograft hypothermic machine perfusion results in a decreased incidence of delayed graft function compared with static cold storage. Ensuring perfusate temperatures remain within the target range of 4-10 °C may impact delayed graft function rates. Project Aims: To identify whether this target was achieved and, if not, whether higher perfusate temperature was associated with delayed graft function. Design: In this retrospective cohort study, transplanted grafts from deceased donors placed on hypothermic machine perfusion pump from June 2019 to August 2020 were analyzed. Measurements were recovered after 5, 15, 60, and 180 min of perfusion. Univariable and multivariable analyses were performed to identify predictors of delayed graft function. Results: A total of 113 grafts from 94 donors were analyzed. Of these, 21 (19%) developed delayed graft function. On univariable logistic regression, variables associated with delayed graft function included older donor age (OR 1.08, P = .002), higher Kidney Donor Profile Index score (OR 1.03, P = .024), and higher 5-min perfusate temperature (T5 min; OR 1.49, P = .014). A higher T5 min was also associated with delayed graft function in multivariable logistic regression models (OR 1.58, P = .005; OR 1.37, P = .08). Grafts with T5 min >10 °C were more likely to experience delayed graft function than those with T5 min <10 °C (OR 4.5, P = .006). Conclusion: Higher early perfusate temperature was an independent predictor of delayed graft function and may be due to inadequate cooling of the circuit prior to placing grafts on pump. Quality improvement initiatives targeting early perfusate temperatures of ≤10 °C may reduce delayed graft function incidence.
与静态冷库相比,同种异体肾移植低温机灌注导致移植物功能延迟的发生率降低。确保灌注温度保持在4-10°C的目标范围内可能会影响延迟的接枝功能速率。项目目的:确定是否达到了这一目标,如果没有,是否较高的灌注温度与延迟移植功能有关。设计:在这项回顾性队列研究中,分析了2019年6月至2020年8月在低温机器灌注泵上放置的已故供体移植移植物。灌注5、15、60和180分钟后恢复测量。进行单变量和多变量分析以确定延迟移植物功能的预测因素。结果:共分析了94例供者的113例移植物。其中21例(19%)出现移植物功能延迟。在单变量logistic回归中,与移植功能延迟相关的变量包括供者年龄较大(OR 1.08, P = 0.002),较高的肾脏供者特征指数评分(OR 1.03, P = 0.024),以及较高的5分钟灌注温度(T5 min;或1.49,p = 0.014)。在多变量logistic回归模型中,较高的T5 min也与延迟移植功能相关(OR 1.58, P = 0.005;或1.37,p = .08)。T5 min (bbb10°C)比T5 min (P = 0.006)更容易出现移植物功能延迟。结论:较高的早期灌注温度是移植物功能延迟的独立预测因子,可能是由于移植物在泵上放置之前回路冷却不足所致。针对早期灌注温度≤10°C的质量改进措施可能会减少延迟移植物功能的发生率。
期刊介绍:
Progress in Transplantation (PIT) is the official journal of NATCO, The Organization for Transplant Professionals. Journal Partners include: Australasian Transplant Coordinators Association and Society for Transplant Social Workers. PIT reflects the multi-disciplinary team approach to procurement and clinical aspects of organ and tissue transplantation by providing a professional forum for exchange of the continually changing body of knowledge in transplantation.