Impact of Premature Ventricular Complex (PVC) Burden on the Left Ventricle in the Structurally Normal Heart: Hemodynamic Alterations of Idiopathic PVC on Echocardiography.
{"title":"Impact of Premature Ventricular Complex (PVC) Burden on the Left Ventricle in the Structurally Normal Heart: Hemodynamic Alterations of Idiopathic PVC on Echocardiography.","authors":"Tien-En Chen, Chun-Cheng Wang, Hong-Chi Ho, Yi-Ching Lai, Hung-Bin Wu, Yen-Nien Lin, Pei-Ying Pai","doi":"10.6515/ACS.202309_39(5).20230119A","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Premature ventricular complex (PVC) without structural heart disease is mostly viewed as a benign arrhythmia. However, the high burden of PVC causes cardiomyopathy due to intraventricular dyssynchrony. The effects of ectopic contraction on left ventricular (LV) hemodynamics in the structurally normal heart are unclear.</p><p><strong>Objectives: </strong>To examine the effect of PVC burden on LV dimension, LV systolic function, and intraventricular blood flow, and to determine whether ectopic ventricular contraction affects LV hemodynamics.</p><p><strong>Methods: </strong>Patients aged ≥ 18 years with PVC ≥ 5% on Holter recording were enrolled and divided into groups G1 (5-10%), G2 (10-20%), and G3 (≥ 20%). We excluded patients with structural heart diseases, pacemakers, and LV systolic dysfunction [LV ejection fraction (LVEF) < 50%]. Clinical characteristics and routine transthoracic echocardiography parameters were compared.</p><p><strong>Results: </strong>The end-systolic LV internal dimension increased according to the PVC burden from G1 to G3 (p = 0.001). LVEF was inversely associated with PVC burden from G1 to G3 (p = 0.002). The same pattern was seen for LV outflow tract (LVOT) maximal velocity (p = 0.005) and maximal pressure gradient (PG) (p = 0.005), LVOT velocity time integral (VTI) (p = 0.03) and LV stroke volume index (LVSI) (p = 0.008).</p><p><strong>Conclusions: </strong>Systolic function and LV end-systolic dimension were inversely associated with PVC burden. Decreased LVOT flow velocity and PG were related to increased PVC burden. LVOT VTI and LVSI were smaller when the PVC burden exceeded 20%. These negative hemodynamic manifestations of idiopathic PVC were considerable even in structure normal hearts, hence the early elimination of PVC is strongly advised.</p>","PeriodicalId":6957,"journal":{"name":"Acta Cardiologica Sinica","volume":"39 5","pages":"687-694"},"PeriodicalIF":1.8000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10499960/pdf/acs-39-687.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Cardiologica Sinica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.6515/ACS.202309_39(5).20230119A","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Premature ventricular complex (PVC) without structural heart disease is mostly viewed as a benign arrhythmia. However, the high burden of PVC causes cardiomyopathy due to intraventricular dyssynchrony. The effects of ectopic contraction on left ventricular (LV) hemodynamics in the structurally normal heart are unclear.
Objectives: To examine the effect of PVC burden on LV dimension, LV systolic function, and intraventricular blood flow, and to determine whether ectopic ventricular contraction affects LV hemodynamics.
Methods: Patients aged ≥ 18 years with PVC ≥ 5% on Holter recording were enrolled and divided into groups G1 (5-10%), G2 (10-20%), and G3 (≥ 20%). We excluded patients with structural heart diseases, pacemakers, and LV systolic dysfunction [LV ejection fraction (LVEF) < 50%]. Clinical characteristics and routine transthoracic echocardiography parameters were compared.
Results: The end-systolic LV internal dimension increased according to the PVC burden from G1 to G3 (p = 0.001). LVEF was inversely associated with PVC burden from G1 to G3 (p = 0.002). The same pattern was seen for LV outflow tract (LVOT) maximal velocity (p = 0.005) and maximal pressure gradient (PG) (p = 0.005), LVOT velocity time integral (VTI) (p = 0.03) and LV stroke volume index (LVSI) (p = 0.008).
Conclusions: Systolic function and LV end-systolic dimension were inversely associated with PVC burden. Decreased LVOT flow velocity and PG were related to increased PVC burden. LVOT VTI and LVSI were smaller when the PVC burden exceeded 20%. These negative hemodynamic manifestations of idiopathic PVC were considerable even in structure normal hearts, hence the early elimination of PVC is strongly advised.
期刊介绍:
Acta Cardiologica Sinica welcomes all the papers in the fields related to cardiovascular medicine including basic research, vascular biology, clinical pharmacology, clinical trial, critical care medicine, coronary artery disease, interventional cardiology, arrythmia and electrophysiology, atherosclerosis, hypertension, cardiomyopathy and heart failure, valvular and structure cardiac disease, pediatric cardiology, cardiovascular surgery, and so on. We received papers from more than 20 countries and areas of the world. Currently, 40% of the papers were submitted to Acta Cardiologica Sinica from Taiwan, 20% from China, and 20% from the other countries and areas in the world. The acceptance rate for publication was around 50% in general.