Identification of a frit-related sample carryover in newborn screening by tandem mass spectrometry

IF 3.1 4区 医学 Q2 MEDICAL LABORATORY TECHNOLOGY
Kyunghun Kim , Howon Lee , Jeong Joong Lee , Kyoungho Cha , Nam Hyun Park , Young Keun Shin , Hyojin Chae , Eun-Jee Oh
{"title":"Identification of a frit-related sample carryover in newborn screening by tandem mass spectrometry","authors":"Kyunghun Kim ,&nbsp;Howon Lee ,&nbsp;Jeong Joong Lee ,&nbsp;Kyoungho Cha ,&nbsp;Nam Hyun Park ,&nbsp;Young Keun Shin ,&nbsp;Hyojin Chae ,&nbsp;Eun-Jee Oh","doi":"10.1016/j.jmsacl.2023.01.001","DOIUrl":null,"url":null,"abstract":"<div><p>The need for high-throughput analysis of multiple analytes for inborn errors of metabolism in newborn screening (NBS) has led to the introduction of tandem mass spectrometry (MS/MS) into the NBS laboratory. In a flow-injection analysis (FIA), the predominant MS/MS method utilized for NBS, samples are introduced directly into the mass spectrometer without chromatographic separation. When a high-throughput FIA-based MS/MS method is implemented on newer generations of mass spectrometers with increased sensitivity, the risk of carryover and contamination increases. In the present study, we report the carryover of ornithine identified during the implementation of the NeoBase™ 2 (PerkinElmer) non-derivatized kits on the Xevo-TQD platform (Waters Corporation) and describe the source of the carryover, which was traced to the stainless-steel frit-type inline filter. Furthermore, a possible compound-dependent interaction with the stainless-steel frit is suggested based on the structure of ornithine and its effect on separation techniques. Investigation and mitigation of carryover can be a time and resource consuming process, and to this end, our report on identification of a stainless-steel frit as the source of delayed elution and carryover of ornithine should be recognized as a rare, albeit possible source of carryover in FIA-MS/MS methods adopted for NST.</p></div>","PeriodicalId":52406,"journal":{"name":"Journal of Mass Spectrometry and Advances in the Clinical Lab","volume":"27 ","pages":"Pages 56-60"},"PeriodicalIF":3.1000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/e3/ba/main.PMC9850200.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Mass Spectrometry and Advances in the Clinical Lab","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2667145X23000019","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

The need for high-throughput analysis of multiple analytes for inborn errors of metabolism in newborn screening (NBS) has led to the introduction of tandem mass spectrometry (MS/MS) into the NBS laboratory. In a flow-injection analysis (FIA), the predominant MS/MS method utilized for NBS, samples are introduced directly into the mass spectrometer without chromatographic separation. When a high-throughput FIA-based MS/MS method is implemented on newer generations of mass spectrometers with increased sensitivity, the risk of carryover and contamination increases. In the present study, we report the carryover of ornithine identified during the implementation of the NeoBase™ 2 (PerkinElmer) non-derivatized kits on the Xevo-TQD platform (Waters Corporation) and describe the source of the carryover, which was traced to the stainless-steel frit-type inline filter. Furthermore, a possible compound-dependent interaction with the stainless-steel frit is suggested based on the structure of ornithine and its effect on separation techniques. Investigation and mitigation of carryover can be a time and resource consuming process, and to this end, our report on identification of a stainless-steel frit as the source of delayed elution and carryover of ornithine should be recognized as a rare, albeit possible source of carryover in FIA-MS/MS methods adopted for NST.

Abstract Image

Abstract Image

用串联质谱法鉴定新生儿筛查中与水果相关的样品携带
新生儿筛查(NBS)中对先天性代谢错误的多种分析物的高通量分析需求导致串联质谱(MS/MS)被引入NBS实验室。在用于NBS的主要MS/MS方法流动注射分析(FIA)中,样品被直接引入质谱仪,而无需色谱分离。当基于FIA的高通量MS/MS方法在灵敏度提高的新一代质谱仪上实施时,携带和污染的风险增加。在本研究中,我们报告了在NeoBase实施过程中发现的鸟氨酸携带情况™ 2(PerkinElmer)在Xevo TQD平台(Waters Corporation)上的非衍生试剂盒,并描述了遗留物的来源,其可追溯到不锈钢玻璃料型在线过滤器。此外,基于鸟氨酸的结构及其对分离技术的影响,提出了可能与不锈钢玻璃料的化合物依赖性相互作用。研究和减少携带可能是一个耗时和耗费资源的过程,为此,我们关于将不锈钢玻璃料确定为延迟洗脱和携带鸟氨酸的来源的报告应被认为是一种罕见的携带来源,尽管在用于NST的FIA-MS/MS方法中可能是携带来源。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Mass Spectrometry and Advances in the Clinical Lab
Journal of Mass Spectrometry and Advances in the Clinical Lab Health Professions-Medical Laboratory Technology
CiteScore
4.30
自引率
18.20%
发文量
41
审稿时长
81 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信