Effect of build orientation on the trueness of occlusal splints fabricated by three-dimensional printing.

IF 1.9 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE
Journal of oral science Pub Date : 2023-10-01 Epub Date: 2023-09-08 DOI:10.2334/josnusd.23-0115
Andrew B Cameron, Keith Tong, Santosh Tadakamadla, Jane L Evans, Menaka Abuzar
{"title":"Effect of build orientation on the trueness of occlusal splints fabricated by three-dimensional printing.","authors":"Andrew B Cameron,&nbsp;Keith Tong,&nbsp;Santosh Tadakamadla,&nbsp;Jane L Evans,&nbsp;Menaka Abuzar","doi":"10.2334/josnusd.23-0115","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Scientific evidence pertaining to the evaluation of trueness of occlusal splints fabricated using different three-dimensional (3D) printers and build orientations compared to subtractive technologies is lacking.</p><p><strong>Methods: </strong>Overall, one hundred and ten occlusal splints were manufactured using two different 3D printers and a dental mill. Five groups of ten were fabricated using the 3D printers at different build orientations (0, 30, 45, 60, and 90 degrees). In addition, a comparison group of ten occlusal splints was subtractively manufactured using a five-axis dental mill. All occlusal splints were scanned and exported as a standard tessellation language file. Analysis was conducted with metrology software with root mean square estimate average positive deviation and average negative deviation used as the measured outcome.</p><p><strong>Results: </strong>The 0 degree printing orientation was the most accurate for printer one with the root mean square value of 0.05 ± 0.01 mm, and 60 degree printing orientation was most accurate for printer two with the RMS value of 0.11 ± 0.01 mm. Subtractively manufactured occlusal splint had significantly higher trueness with the lowest RMS value of 0.03 ± 0.05 mm.</p><p><strong>Conclusion: </strong>Build orientations influence the trueness of additively manufactured occlusal splints while occlusal splints produced by subtractive manufacturing were statistically significantly more accurate.</p>","PeriodicalId":16646,"journal":{"name":"Journal of oral science","volume":null,"pages":null},"PeriodicalIF":1.9000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of oral science","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.2334/josnusd.23-0115","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/9/8 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Scientific evidence pertaining to the evaluation of trueness of occlusal splints fabricated using different three-dimensional (3D) printers and build orientations compared to subtractive technologies is lacking.

Methods: Overall, one hundred and ten occlusal splints were manufactured using two different 3D printers and a dental mill. Five groups of ten were fabricated using the 3D printers at different build orientations (0, 30, 45, 60, and 90 degrees). In addition, a comparison group of ten occlusal splints was subtractively manufactured using a five-axis dental mill. All occlusal splints were scanned and exported as a standard tessellation language file. Analysis was conducted with metrology software with root mean square estimate average positive deviation and average negative deviation used as the measured outcome.

Results: The 0 degree printing orientation was the most accurate for printer one with the root mean square value of 0.05 ± 0.01 mm, and 60 degree printing orientation was most accurate for printer two with the RMS value of 0.11 ± 0.01 mm. Subtractively manufactured occlusal splint had significantly higher trueness with the lowest RMS value of 0.03 ± 0.05 mm.

Conclusion: Build orientations influence the trueness of additively manufactured occlusal splints while occlusal splints produced by subtractive manufacturing were statistically significantly more accurate.

构建方向对三维打印制作的咬合夹板真实性的影响。
目的:与消减技术相比,缺乏关于评估使用不同三维(3D)打印机和构建方向制造的咬合夹板真实性的科学证据。方法:总共使用两台不同的3D打印机和一台牙科研磨机制造了110个咬合夹板。使用3D打印机以不同的构建方向(0度、30度、45度、60度和90度)制造了五组,每组10人。此外,使用五轴牙磨机减去制造了10个咬合夹板的对照组。所有咬合夹板都被扫描并导出为标准镶嵌语言文件。使用计量软件进行分析,使用均方根估计平均正偏差和平均负偏差作为测量结果。结果:打印机1的0度打印方向最准确,均方根值为0.05±0.01mm,而打印机2的60度打印方向则最准确,RMS值为0.11±0.01mm。减法制造的咬合夹板具有显著更高的真实度,最低RMS值为0.03±0.05mm。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of oral science
Journal of oral science DENTISTRY, ORAL SURGERY & MEDICINE-MATERIALS SCIENCE, BIOMATERIALS
CiteScore
3.80
自引率
0.00%
发文量
58
期刊介绍: Information not localized
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信