Evaluation of Iodinated Contrast Media Use in Abdominal CT Scans in Cancer Assessments: A Cross-Sectional Study in Lomé (Togo).

IF 2.2 Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Pihou Gbande, Bidamin N'timon, Dermane Alassani Tchakpedeou, Mazamaesso Tchaou, Kokou Adambounou, Lantam Sonhaye, Lama Kegdigoma Agoda-Koussema, Komlanvi Adjenou
{"title":"Evaluation of Iodinated Contrast Media Use in Abdominal CT Scans in Cancer Assessments: A Cross-Sectional Study in Lomé (Togo).","authors":"Pihou Gbande,&nbsp;Bidamin N'timon,&nbsp;Dermane Alassani Tchakpedeou,&nbsp;Mazamaesso Tchaou,&nbsp;Kokou Adambounou,&nbsp;Lantam Sonhaye,&nbsp;Lama Kegdigoma Agoda-Koussema,&nbsp;Komlanvi Adjenou","doi":"10.1155/2023/8296467","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>There is great variability between centers regarding contrast injection protocols. They should only be injected if they can provide useful information for diagnosis with the necessary and sufficient quantity of iodine. We wanted to know through this study if the use of iodinated contrast media is optimised in abdominal CT scans performed for cancer assessment in Lomé.</p><p><strong>Materials and methods: </strong>It was a cross-sectional, descriptive, and analytical study with a prospective collection over a period of 6 months in three CT units in Lomé. It involved abdominal CT scans performed for oncological evaluation. Data were reported as the mean ± standard deviation. The Pearson correlation coefficient, ANOVA, chi-square, and the Fisher test were used.</p><p><strong>Results: </strong>A total of 218 examinations were recorded. The female sex represented 56.88% of the patients. The mean age was 50.92 ± 15.78 years. The mean weight was 70.46 ± 15.23 kg. The mean BMI was 24.91 ± 5.32 kg/m<sup>2</sup>. The examinations were performed with a voltage of 120 kV in 195 cases (89.45%). The mean dose of injected iodine was 0.42 ± 0.09 gI/kg with a dose of 0.40 gI/kg at 80 kV and 0.45 gI/kg at 130 kV. The mean injection rate was 2.90 ± 0.34 mL/s. The mean injected volume was 83.19 ± 7.29 mL. The mean duration of the injection was 30.60 ± 7.39 s. The mean iodine delivery rate was 0.98 ± 0.17 gI/s. There was no saline injection in 152 cases (69.72%). Liver contrast enhancement was satisfactory in 94.5% of cases. There was a strong negative linear correlation between the dose of injected iodine and weight.</p><p><strong>Conclusions: </strong>Optimization guidelines for the use of iodinated contrast media are not always applied. Therefore, monitoring and benchmarking programmes for iodinated contrast injection protocols that involve all radiology personnel should be implemented.</p>","PeriodicalId":51864,"journal":{"name":"Radiology Research and Practice","volume":"2023 ","pages":"8296467"},"PeriodicalIF":2.2000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9836791/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiology Research and Practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2023/8296467","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Background: There is great variability between centers regarding contrast injection protocols. They should only be injected if they can provide useful information for diagnosis with the necessary and sufficient quantity of iodine. We wanted to know through this study if the use of iodinated contrast media is optimised in abdominal CT scans performed for cancer assessment in Lomé.

Materials and methods: It was a cross-sectional, descriptive, and analytical study with a prospective collection over a period of 6 months in three CT units in Lomé. It involved abdominal CT scans performed for oncological evaluation. Data were reported as the mean ± standard deviation. The Pearson correlation coefficient, ANOVA, chi-square, and the Fisher test were used.

Results: A total of 218 examinations were recorded. The female sex represented 56.88% of the patients. The mean age was 50.92 ± 15.78 years. The mean weight was 70.46 ± 15.23 kg. The mean BMI was 24.91 ± 5.32 kg/m2. The examinations were performed with a voltage of 120 kV in 195 cases (89.45%). The mean dose of injected iodine was 0.42 ± 0.09 gI/kg with a dose of 0.40 gI/kg at 80 kV and 0.45 gI/kg at 130 kV. The mean injection rate was 2.90 ± 0.34 mL/s. The mean injected volume was 83.19 ± 7.29 mL. The mean duration of the injection was 30.60 ± 7.39 s. The mean iodine delivery rate was 0.98 ± 0.17 gI/s. There was no saline injection in 152 cases (69.72%). Liver contrast enhancement was satisfactory in 94.5% of cases. There was a strong negative linear correlation between the dose of injected iodine and weight.

Conclusions: Optimization guidelines for the use of iodinated contrast media are not always applied. Therefore, monitoring and benchmarking programmes for iodinated contrast injection protocols that involve all radiology personnel should be implemented.

Abstract Image

碘造影剂在腹部CT扫描中用于癌症评估的评估:一项在lomoise(多哥)的横断面研究。
背景:不同中心的对比剂注射方案差异很大。只有当它们能够提供有用的诊断信息时,才应注射必要和足够量的碘。我们想通过这项研究了解碘造影剂的使用在lomoise进行的腹部CT扫描中是否被优化用于癌症评估。材料和方法:这是一项横断面、描述性和分析性研究,在lom的三个CT单元中进行了为期6个月的前瞻性收集。它包括进行腹部CT扫描以进行肿瘤评估。数据以平均值±标准差报告。采用Pearson相关系数、方差分析、卡方检验和Fisher检验。结果:共记录检查218例。女性占56.88%。平均年龄50.92±15.78岁。平均体重70.46±15.23 kg。平均BMI为24.91±5.32 kg/m2。195例(89.45%)在120 kV电压下进行检查。注射碘的平均剂量为0.42±0.09 gI/kg,其中80 kV剂量为0.40 gI/kg, 130 kV剂量为0.45 gI/kg。平均注射速率为2.90±0.34 mL/s。平均注射量为83.19±7.29 mL。平均注射时间30.60±7.39 s。平均碘递送率为0.98±0.17 gI/s。未注射生理盐水152例(69.72%)。94.5%的病例肝脏增强效果满意。注射碘的剂量与体重之间存在很强的负线性相关。结论:碘造影剂使用的优化指南并不总是适用。因此,应该实施涉及所有放射学人员的碘造影剂注射方案的监测和基准规划。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Radiology Research and Practice
Radiology Research and Practice RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
自引率
0.00%
发文量
17
审稿时长
17 weeks
期刊介绍: Radiology Research and Practice is a peer-reviewed, Open Access journal that publishes articles on all areas of medical imaging. The journal promotes evidence-based radiology practice though the publication of original research, reviews, and clinical studies for a multidisciplinary audience. Radiology Research and Practice is archived in Portico, which provides permanent archiving for electronic scholarly journals, as well as via the LOCKSS initiative. It operates a fully open access publishing model which allows open global access to its published content. This model is supported through Article Processing Charges. For more information on Article Processing charges in gen
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信