Nuclear medicine staff exposure to ionising radiation in 18F-FDG PET/CT practice: a preliminary retrospective study.

IF 1.7 4区 医学 Q3 PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH
Bojan Pavičar, Jasna Davidović, Biljana Petrović, Goran Vuleta, Saša Trivić, Vlatko Šajinović, Nataša Egeljić-Mihailović, Nataša Todorović, Branko Predojević
{"title":"Nuclear medicine staff exposure to ionising radiation in <sup>18</sup>F-FDG PET/CT practice: a preliminary retrospective study.","authors":"Bojan Pavičar,&nbsp;Jasna Davidović,&nbsp;Biljana Petrović,&nbsp;Goran Vuleta,&nbsp;Saša Trivić,&nbsp;Vlatko Šajinović,&nbsp;Nataša Egeljić-Mihailović,&nbsp;Nataša Todorović,&nbsp;Branko Predojević","doi":"10.2478/aiht-2021-72-3517","DOIUrl":null,"url":null,"abstract":"<p><p>This retrospective study provides an insight into the levels of radiation exposure of six nuclear medicine (NM) staff (four technologists and two nurses) performing routine diagnostic <sup>18</sup>F-fluorodeoxyglucose (<sup>18</sup>F-FDG) positron emission tomography-computed tomography (PET/CT) at the University Clinical Centre of the Republic of Srpska, Department of Nuclear Medicine and Thyroid Disorders, Banja Luka, Bosnia and Herzegovina. Data analysis included monthly staff exposure measured with personal thermoluminescent dosimeters (TLD) between June and December 2018, quantified in terms of normalised dose for the whole body [Hp(10)] and dominant hand [Hp(0.07)] and their comparison between each staff member and between the two groups (technologists and nurses). The study goal was to establish how our Department compared with reports from other PET/CT centres worldwide in terms of annual number of procedures and exposure limits and whether there could be room for further improvements in radiation protection. The number of procedures rose considerably from 208 in 2016 to 876 in 2019 and was 423 in the observed seven-month period. Mean individual whole-body exposure dose per GBq of injected <sup>18</sup>F-FDG activity, [Hp(10)/A] was 18.55 μSv/GBq for the four technologists and 15.61 μSv/GBq for the two nurses. Mean dominant-hand exposure dose per GBq of injected <sup>18</sup>F-FDG activity [Hp(0.07)/A] was 16.99 μSv/GBq and 25.44 μSv/GBq for the two groups, respectively. The average annual cumulative dose for all staff was (1.06±0.29) mSv for Hp(10) and (1.15±0.32) mSv for Hp(0.07). These results are comparable with those of similar studies. Staff doses were well below the annual limits. Nurses received slightly higher extremity doses than technologists. In view of the increasing trends in the number of PET/CT procedures, dose monitoring should be continued to identify exposure hotspots and maintain doses as low as possible.</p>","PeriodicalId":55462,"journal":{"name":"Arhiv Za Higijenu Rada I Toksikologiju-Archives of Industrial Hygiene and Toxicology","volume":"72 3","pages":"216-224"},"PeriodicalIF":1.7000,"publicationDate":"2021-09-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/a3/7f/aiht-72-216.PMC8576747.pdf","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Arhiv Za Higijenu Rada I Toksikologiju-Archives of Industrial Hygiene and Toxicology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2478/aiht-2021-72-3517","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH","Score":null,"Total":0}
引用次数: 4

Abstract

This retrospective study provides an insight into the levels of radiation exposure of six nuclear medicine (NM) staff (four technologists and two nurses) performing routine diagnostic 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography-computed tomography (PET/CT) at the University Clinical Centre of the Republic of Srpska, Department of Nuclear Medicine and Thyroid Disorders, Banja Luka, Bosnia and Herzegovina. Data analysis included monthly staff exposure measured with personal thermoluminescent dosimeters (TLD) between June and December 2018, quantified in terms of normalised dose for the whole body [Hp(10)] and dominant hand [Hp(0.07)] and their comparison between each staff member and between the two groups (technologists and nurses). The study goal was to establish how our Department compared with reports from other PET/CT centres worldwide in terms of annual number of procedures and exposure limits and whether there could be room for further improvements in radiation protection. The number of procedures rose considerably from 208 in 2016 to 876 in 2019 and was 423 in the observed seven-month period. Mean individual whole-body exposure dose per GBq of injected 18F-FDG activity, [Hp(10)/A] was 18.55 μSv/GBq for the four technologists and 15.61 μSv/GBq for the two nurses. Mean dominant-hand exposure dose per GBq of injected 18F-FDG activity [Hp(0.07)/A] was 16.99 μSv/GBq and 25.44 μSv/GBq for the two groups, respectively. The average annual cumulative dose for all staff was (1.06±0.29) mSv for Hp(10) and (1.15±0.32) mSv for Hp(0.07). These results are comparable with those of similar studies. Staff doses were well below the annual limits. Nurses received slightly higher extremity doses than technologists. In view of the increasing trends in the number of PET/CT procedures, dose monitoring should be continued to identify exposure hotspots and maintain doses as low as possible.

Abstract Image

Abstract Image

Abstract Image

核医学工作人员在18F-FDG PET/CT工作中电离辐射暴露:初步回顾性研究
这项回顾性研究深入了解了波斯尼亚和黑塞哥维那巴尼亚卢卡塞族共和国大学临床中心核医学和甲状腺疾病系6名核医学(NM)工作人员(4名技术人员和2名护士)进行常规诊断18f -氟脱氧葡萄糖(18F-FDG)正电子发射断层扫描-计算机断层扫描(PET/CT)的辐射暴露水平。数据分析包括2018年6月至12月期间使用个人热释光剂量计(TLD)测量的每月工作人员暴露量,以全身[Hp(10)]和惯用手[Hp(0.07)]的标准化剂量进行量化,以及每个工作人员之间以及两组(技术人员和护士)之间的比较。这项研究的目的是确定本处与世界各地其他PET/CT中心的报告相比,在每年的程序数量和照射限值方面如何,以及在辐射防护方面是否有进一步改进的空间。手术数量从2016年的208例大幅增加到2019年的876例,在观察的7个月期间为423例。4名技术人员注射18F-FDG活度的平均个体全身暴露剂量[Hp(10)/A]为18.55 μSv/GBq, 2名护士为15.61 μSv/GBq。两组注射18F-FDG活性[Hp(0.07)/A]的平均优势手暴露剂量分别为16.99 μSv/GBq和25.44 μSv/GBq。所有工作人员的年平均累积剂量分别为Hp(10)(1.06±0.29)mSv和Hp(0.07)(1.15±0.32)mSv。这些结果与同类研究的结果具有可比性。工作人员的剂量远低于年度限制。护士接受的四肢剂量略高于技术人员。鉴于PET/CT检查次数呈增加趋势,应继续进行剂量监测,以确定暴露热点,并保持尽可能低的剂量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Arhiv Za Higijenu Rada I Toksikologiju-Archives of Industrial Hygiene and Toxicology
Arhiv Za Higijenu Rada I Toksikologiju-Archives of Industrial Hygiene and Toxicology PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH-TOXICOLOGY
CiteScore
3.50
自引率
4.80%
发文量
26
审稿时长
6-12 weeks
期刊介绍: Archives of Industrial Hygiene and Toxicology (abbr. Arh Hig Rada Toksikol) is a peer-reviewed biomedical scientific quarterly that publishes contributions relevant to all aspects of environmental and occupational health and toxicology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信