Optic Nerve Head Parameters in Saudi Male Young Adults Using Swept-source Optical Coherence Tomography.

Q3 Medicine
Naveen K Challa
{"title":"Optic Nerve Head Parameters in Saudi Male Young Adults Using Swept-source Optical Coherence Tomography.","authors":"Naveen K Challa","doi":"10.5005/jp-journals-10078-1405","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To assess the optic nerve head (ONH) parameters in normal male Saudi eyes using swept-source optical coherence tomography (SS-OCT).</p><p><strong>Materials and methods: </strong>The study included 86 healthy men with a mean age of 23.6 ± 4.82 years. The metrics collected using SS-OCT from each individual was disk area (DA), rim area (RA), cup volume (CV), linear cup-disk ratio (LCDR), vertical cup-disk ratio (VCDR), and total retinal nerve fiber layer (RNFL) thickness, superior RNFL thickness, and inferior RNFL thickness. All the metrics were correlated with the DA. The right eye data were used for the correlation analysis.</p><p><strong>Results: </strong>The mean DA in OD was 1.78 mm<sup>2</sup> (range 1.09-2.70 mm<sup>2</sup>). The mean RA was 1.28 mm<sup>2</sup> (range 0.72-2.47 mm<sup>2</sup>). The DA showed a significant positive correlation (<i>p</i> < 0.05) with RA, cup area (CA), CV, VCDR, LCDR, and total RNFL thickness.</p><p><strong>Conclusion: </strong>For the first time, using sweeping source OCT (DRI OCT Triton, Topcon Corporation), a normative database of ONH parameters was made accessible to the Saudi male population. While assessing the optic disk for progressive optic neuropathies like glaucoma, disk size should be taken into consideration since the optic DA affects ONH topography, especially in Saudi eyes.</p><p><strong>How to cite this article: </strong>Challa NK. Optic Nerve Head Parameters in Saudi Male Young Adults Using Swept-source Optical Coherence Tomography. J Curr Glaucoma Pract 2023;17(2):58-62.</p>","PeriodicalId":15419,"journal":{"name":"Journal of Current Glaucoma Practice","volume":"17 2","pages":"58-62"},"PeriodicalIF":0.0000,"publicationDate":"2023-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/cb/e3/jocgp-17-58.PMC10357028.pdf","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Current Glaucoma Practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5005/jp-journals-10078-1405","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 1

Abstract

Purpose: To assess the optic nerve head (ONH) parameters in normal male Saudi eyes using swept-source optical coherence tomography (SS-OCT).

Materials and methods: The study included 86 healthy men with a mean age of 23.6 ± 4.82 years. The metrics collected using SS-OCT from each individual was disk area (DA), rim area (RA), cup volume (CV), linear cup-disk ratio (LCDR), vertical cup-disk ratio (VCDR), and total retinal nerve fiber layer (RNFL) thickness, superior RNFL thickness, and inferior RNFL thickness. All the metrics were correlated with the DA. The right eye data were used for the correlation analysis.

Results: The mean DA in OD was 1.78 mm2 (range 1.09-2.70 mm2). The mean RA was 1.28 mm2 (range 0.72-2.47 mm2). The DA showed a significant positive correlation (p < 0.05) with RA, cup area (CA), CV, VCDR, LCDR, and total RNFL thickness.

Conclusion: For the first time, using sweeping source OCT (DRI OCT Triton, Topcon Corporation), a normative database of ONH parameters was made accessible to the Saudi male population. While assessing the optic disk for progressive optic neuropathies like glaucoma, disk size should be taken into consideration since the optic DA affects ONH topography, especially in Saudi eyes.

How to cite this article: Challa NK. Optic Nerve Head Parameters in Saudi Male Young Adults Using Swept-source Optical Coherence Tomography. J Curr Glaucoma Pract 2023;17(2):58-62.

Abstract Image

Abstract Image

Abstract Image

沙特年轻男性视神经头参数扫描源光学相干断层扫描。
目的:使用扫描源光学相干断层扫描(SS-OCT)评估沙特正常男性眼睛的视神经头(ONH)参数。材料和方法:该研究包括86名平均年龄23.6±4.82岁的健康男性。使用SS-OCT从每个个体收集的指标是椎间盘面积(DA)、边缘面积(RA)、杯体积(CV)、线性杯盘比(LCDR)、垂直杯盘比和总视网膜神经纤维层(RNFL)厚度、上RNFL厚度和下RNFL厚度。所有指标均与DA相关。右眼数据用于相关性分析。结果:OD的平均DA为1.78mm2(范围1.09-2.70mm2)。平均RA为1.28 mm2(范围0.72-2.47 mm2)。DA与RA、杯面积(CA)、CV、VCDR、LCDR和总RNFL厚度呈显著正相关(p<0.05)。结论:使用扫描源OCT(DRI OCT Triton,Topcon Corporation),首次为沙特男性人群提供了ONH参数的标准数据库。在评估进行性视神经病变(如青光眼)的视盘时,应考虑视盘大小,因为视DA会影响ONH地形图,尤其是沙特眼。如何引用这篇文章:Challa NK。沙特年轻男性视神经头参数扫描源光学相干断层扫描。青光眼临床杂志2023;17(2):58-62。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Current Glaucoma Practice
Journal of Current Glaucoma Practice Medicine-Ophthalmology
CiteScore
1.00
自引率
0.00%
发文量
38
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信